Values below come from the supplied range information. A reference configuration is not a confirmed order specification. Ask us to verify the exact model, interfaces and operating conditions.
Range illustration. Exact model appearance and configuration may differ.
01 / 12
IP-LXM04Z
Parameters
Model
IP-LXM04Z
Dimensions
L: mm (in): 257.0 (10.33) · C: mm (in): 146.7 (5.78)
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Range illustration. Exact model appearance and configuration may differ.
07 / 12
KLX-500
Parameters
Model
KLX-500
Dimensions
L (mm): 270 · W (mm): 320 · H (mm): 605
Flow
Reference flow (t/h): 0.5
Pressure
Model-specific; confirm the current datasheet.
Application
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Range illustration. Exact model appearance and configuration may differ.
08 / 12
KLX-1000
Parameters
Model
KLX-1000
Dimensions
L (mm): 345 · W (mm): 320 · H (mm): 605
Flow
Reference flow (t/h): 1
Pressure
Model-specific; confirm the current datasheet.
Application
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Range illustration. Exact model appearance and configuration may differ.
09 / 12
KLX-2000
Parameters
Model
KLX-2000
Dimensions
L (mm): 500 · W (mm): 320 · H (mm): 605
Flow
Reference flow (t/h): 2
Pressure
Model-specific; confirm the current datasheet.
Application
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Range illustration. Exact model appearance and configuration may differ.
10 / 12
KLX-3000
Parameters
Model
KLX-3000
Dimensions
L (mm): 660 · W (mm): 320 · H (mm): 605
Flow
Reference flow (t/h): 3
Pressure
Model-specific; confirm the current datasheet.
Application
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Range illustration. Exact model appearance and configuration may differ.
11 / 12
KLX-4000
Parameters
Model
KLX-4000
Dimensions
L (mm): 820 · W (mm): 320 · H (mm): 605
Flow
Reference flow (t/h): 4
Pressure
Model-specific; confirm the current datasheet.
Application
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Range illustration. Exact model appearance and configuration may differ.
12 / 12
KLX-5000
Parameters
Model
KLX-5000
Dimensions
L (mm): 930 · W (mm): 320 · H (mm): 605
Flow
Reference flow (t/h): 5
Pressure
Model-specific; confirm the current datasheet.
Application
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
Electrodeionization modules and laboratory purification equipment for high-purity water workflows.
Key Advantages & Selection Notes
IONPURE LX-Z and KLXHM module families appear in the supplied product documents
Documented module capacities vary by model; feedwater and system design affect the final selection
Laboratory ultrapure-water systems are also available as a separate range
Model Comparison & Technical Data
EDI & Ultrapure Water Modules · reference table 1
Model
Design product flow: m³/h (gpm)
Minimum flow: m³/h (gpm)
IP-LXM04Z
0.44–0.67 (2.0–3.0)
0.22 (1.0)
IP-LXM10Z
1.1–1.65 (5.0–7.5)
0.55 (2.5)
IP-LXM18Z
2.0–3.1 (9.0–13.5)
1.1 (4.5)
IP-LXM24Z
2.8–4.2 (12.5–18.8)
1.4 (6.3)
IP-LXM30Z
3.4–5.1 (15.0–22.5)
1.7 (7.5)
IP-LXM45Z
5.1–7.7 (12.5–33.7)
2.55 (11.25)
EDI & Ultrapure Water Modules · reference table 2
Model
DC voltage (V)
DC current (A)
Shipping weight: kg (lb)
Operating weight: kg (lb)
IP-LXM04Z
0–55
0–6
68 (150)
45 (100)
IP-LXM10Z
0–135
0–6
91 (200)
68 (150)
IP-LXM18Z
0–240
0–6
100 (220)
77 (170)
IP-LXM24Z
0–320
0–6
113 (250)
91 (200)
IP-LXM30Z
0–400
0–6
123 (270)
100 (220)
IP-LXM45Z
0–600
0–6
148 (325)
124 (273)
EDI & Ultrapure Water Modules · reference table 3
Model
L: mm (in)
C: mm (in)
IP-LXM04Z
257.0 (10.33)
146.7 (5.78)
IP-LXM10Z
346.1 (13.63)
235.6 (9.28)
IP-LXM18Z
464.0 (18.30)
353.9 (13.93)
IP-LXM24Z
553.2 (21.78)
442.7 (17.42)
IP-LXM30Z
665.3 (26.19)
531.1 (20.92)
IP-LXM45Z
886.1 (34.88)
752.7 (29.65)
EDI & Ultrapure Water Modules · reference table 4
Model
Reference flow (t/h)
Matching power supply
KLX-500
0.5
FEC-1200
KLX-1000
1
FEC-1200
KLX-2000
2
FEC-1200
KLX-3000
3
FEC-2000
KLX-4000
4
FEC-2000
KLX-5000
5
FEC-2000
EDI & Ultrapure Water Modules · reference table 5
Model
L (mm)
W (mm)
H (mm)
KLX-500
270
320
605
KLX-1000
345
320
605
KLX-2000
500
320
605
KLX-3000
660
320
605
KLX-4000
820
320
605
KLX-5000
930
320
605
Specifications are subject to confirmation for the exact model. Test conditions, units, dimensions, materials, packing, performance and certificates must be checked against the current datasheet. “To be confirmed” and “not provided” are not performance commitments.
Typical Applications
High-purity process water for industrial, electronics, laboratory and other applications requiring a defined feedwater and product-water specification.
✓Existing manufacturer and complete model number
✓Feedwater analysis, flow, temperature, pressure and current configuration
✓Required output or gas-management target and replacement restrictions
Nominal membrane flow and salt rejection are manufacturer test values. Review the test conditions alongside the numbers; they are not a guarantee of output in a different installation.
CUSTOMER PERSPECTIVES
Experience shared by our customers.
System Integrator
⭐️⭐️⭐️⭐️⭐️
“We needed replacement components for an existing RO system. Their team checked dimensions and connection specifications before shipment, which saved us considerable installation time.
Better alignment between design, components and site requirements.
System Integrator | Middle East
LET’S KEEP IN TOUCH
We’re here to listen.
A question, a photograph or a complete BOM. Start wherever you are; we will work through the next details together.