Values below come from the supplied range information. A reference configuration is not a confirmed order specification. Ask us to verify the exact model, interfaces and operating conditions.
Range illustration. Exact model appearance and configuration may differ.
01 / 11
WH-PP-300
Parameters
Model
WH-PP-300
Dimensions
Pore size: 0.1–0.2 μm
Flow
Model-specific; confirm the current datasheet.
Pressure
Model-specific; confirm the current datasheet.
Application
Dissolved-gas management in process-water and high-purity-water systems. Gas target, flow and operating mode determine the relevant contactor.
Accessories
Liquid and gas-side connectors, seals and vacuum / sweep-gas arrangements require model confirmation.Contact us for more information ↗
Hollow-fibre contactor options for process water applications where dissolved-gas management matters.
Key Advantages & Selection Notes
Industrial and laboratory-use product materials are included
Model selection depends on target gas, flow, water chemistry and operating conditions
Performance figures and compatible accessories should be confirmed against the chosen model
Model Comparison & Technical Data
Degassing Membrane Contactors · reference table 1
Membrane material
Model
Pore size
Membrane area
PP
WH-PP-300
0.1–0.2 μm
0.75 m²
PES
WH-PES-300
0.01–0.2 μm / optional
1.3 m²
PVDF
WH-PVDF-300
0.01–0.1 μm
1 m²
PVC
WH-PVC-300
0.01–0.2 μm / optional
1 m²
PAN
WH-PAN-300
0.01–0.1 μm
1 m²
PS
To be confirmed
To be confirmed
To be confirmed
Degassing Membrane Contactors · reference table 2
Model
Length (mm)
Ø1 (mm)
Ø2 (mm)
Design water flow
Membrane area (m²)
Liquid pressure
Vacuum requirement
D4×80
1000
32
90
0.3–1.0 T/h
12
<0.2 MPa
>0.096 MPa
D5×80
1000
32
140
0.8–2.5 T/h
25
<0.2 MPa
>0.096 MPa
D6×80
1000
40
160
1.0–3.5 T/h
46
<0.2 MPa
>0.096 MPa
D8×80
1000
50
200
2.0–4.5 T/h
65
<0.2 MPa
>0.096 MPa
D10×80
1000
50
250
2.5–5.5 T/h
80
<0.2 MPa
>0.096 MPa
Specifications are subject to confirmation for the exact model. Test conditions, units, dimensions, materials, packing, performance and certificates must be checked against the current datasheet. “To be confirmed” and “not provided” are not performance commitments.
Typical Applications
Dissolved-gas management in process-water and high-purity-water systems. Gas target, flow and operating mode determine the relevant contactor.
✓Existing manufacturer and complete model number
✓Feedwater analysis, flow, temperature, pressure and current configuration
✓Required output or gas-management target and replacement restrictions
Nominal membrane flow and salt rejection are manufacturer test values. Review the test conditions alongside the numbers; they are not a guarantee of output in a different installation.
CUSTOMER PERSPECTIVES
Experience shared by our customers.
System Integrator
⭐️⭐️⭐️⭐️⭐️
“We needed replacement components for an existing RO system. Their team checked dimensions and connection specifications before shipment, which saved us considerable installation time.
Better alignment between design, components and site requirements.
System Integrator | Middle East
LET’S KEEP IN TOUCH
We’re here to listen.
A question, a photograph or a complete BOM. Start wherever you are; we will work through the next details together.